Titebond

TITEBOND 920 CLEAR THIN-SPREAD TILE ADHESIVE

Titebond 920 is an environmentally-safe, pressure sensitive, latex flooring adhesive for the installation of vinyl composition tiles, foam backed hardwood parquet and cork/foam underlayment. Its high tack and fast drying capabilities help relieve edge curl on VCT and minimize tile movement. The adhesive also dries clear so that layout lines remain visible during installation. It has a maximum open time of 24 hours* to allow for long installations and repositionability. It may be used over standard construction and select sealed surfaces. Titebond 920 contains no volatile solvents, no hazardous materials and no carcinogens. There is no unpleasant or lingering odor. It is freeze/thaw stable (5 cycles), nonflammable, water-resistant and nontoxic.

*Protect open adhesive from dust and debris.

Features & Benefits


  • Meets LEEDv4
  • Ideal for vinyl composition tile (VCT), foam backed hardwood parquet & cork/foam underlayment
  • Pressure sensitive adhesive
  • Advanced latex adhesive for strong bond strength
  • High tack to minimize tile movement
  • 24 hour* repositionability
  • Freeze/thaw stable
  • Water resistant
  • Nonflammable
  • Non-toxic
  • 7 lbs. or 90% RH moisture limitation
  • Product is FloorScore® certified by SCS

Application Guidelines


  • Suitable Substrates: Refer to the flooring manufacturer’s specific recommendations for suitable substrates. Porous: Concrete, well-bonded cementitious underlayments, APA grade underlayment plywood (untreated) and radiant-heated subfloors where temperatures do not exceed 85°F (29.4°C) on all grade levels. Also can be used over well-bonded, properly primed gypsum underlayments (above-grade only). Non-porous: Ceramic tile, terrazzo, marble, certain epoxy coatings and existing well-bonded resilient flooring (not perimeter bonded or cushion-backed). Please note that all substrates must be sound, solid and well-bonded.
  • Subfloor Preparation: All substrates must be clean, dry, structurally sound, properly cured and free of dirt, oil, paint, old adhesive, wax, sealers and curing agents. General scouring with 20 grit or #3 1/2 open-coat sandpaper will remove most compounds. All loose materials must be vacuumed from the surface after scouring. The subfloor must be flat to a tolerance of 3/16” in a 10’ radius. Grinding concrete floors is preferred over the use of filling compounds. If filling/flattening compounds are used, they must be Portland-based cementitious material and have a compressive strength equal to or greater than 3000 psi when cured. Moisture level in concrete subfloor will fluctuate. Any cementitious material used must be rated for the highest moisture content possible. Consult the cementitious material manufacturer’s application directions. Use of adhesive over lightweight concrete and all gypsum-based materials requires the use of an approved concrete primer prior to application of adhesive. The substrate, adhesive and flooring must be acclimated in an enclosed building with the HVAC operational between 60-95°F (15-35°C), and between 30-65% relative humidity, for at least 72 hours before, during and after the installation.
  • Subfloor Moisture Check and Alkali: Concrete subfloors should be tested for moisture prior to installation. Moisture levels cannot be greater than 7 lbs./1000 sq. ft./24 hours on a Calcium Chloride Test (ASTM F1869), or relative humidity (RH) of 90% or less when tested with an in situ probe (ASTM F2170). Alkali needs to be checked and should be in the range of 5-9. When installing directly over wood subfloors the moisture content of the subfloor, foam backed hardwood parquet and cork/foam underlayment should be 13% or less.
  • Floor Covering Recommendations: Vinyl Composition Tile (VCT), Foam Backed Hardwood Parquet & Cork/Foam Underlayment.
  • Installation Recommendations: For VCT, apply Titebond 920 using one of the following trowels. On smooth surfaces use a 1/32” x 1/32” U-notched trowel at the rate of 250 square feet per gallon. On rougher surfaces use a 1/16” x 1/16” x 1/16” notched trowel. When using Titebond 920 over porous substrates a larger trowel must be used. For cork/foam underlayment, please follow manufacturers installation recommendations. Minimum open time is an hour after adhesive application, or until it has become nearly clear and no longer transfers to the finger upon light touch. Maximum open time is 24 hours. If applied adhesive becomes covered with foreign matter, it will be necessary to apply an additional coat in order to promote adhesion. When adhesive is ready, set tiles in place (they will not slide). Roll within 12 hours with a heavy linoleum roller. Restrict heavy traffic for 24 hours. Do not expose floor to water for 10 days after installation. Follow flooring manufacturers recommendations for sealing/waxing VCT.
  • Cleanup: Clean wet adhesive with water. Clean dry adhesive with mineral spirits. Follow solvent vendor’s safety precautions.

Trowel Recommendations and Coverage

FLOORING TYPE TROWEL SIZE TROWEL TYPE COVERAGE
VINYL COMPOSITION TILE (VCT) 1/32" U-NOTCH APPROXIMATELY 250 SQ. FT. PER GALLON
  1/16" SQUARE-NOTCH APPROXIMATELY 150 SQ. FT. PER GALLON
FOAM BACKED HARWOOD PARQUET 3/32 SQUARE-NOTCH APPROXIMATELY 135 SQ. FT. PER GALLON
  1/8" SQUARE-NOTCH APPROXIMATELY 99 SQ. FT. PER GALLON
CORK/FOAM UNDERLAYMENT 1/16" x 1/16" x 1/16" SQUARE-NOTCH APPROXIMATELY 50 SQ. FT. PER GALLON
CLEAN TROWEL WITH WATER OFTEN TO PREVENT ADHESIVE BUILD-UP.

Physical Properties


  • Type: Latex
  • Calculated VOC: < 50 g/L
  • Color: Beige
  • Flashpoint: > 200°F (Pensky-Martens Closed Cup)
  • Weight Per Gallon: 9.26 lbs.
  • Solids: 64.5%
  • Freeze / Thaw Stability: Stable (5 cycles at 20 °F.)
  • Viscosity: Roller or trowel
  • Storage Life: 24 months in tightly closed container

Limitations


Do not use over high alkaline concrete (over 9.0 pH). Do not use over or under solid vinyl tile or sheets goods. Do not store below freezing. Use in well-ventilated area. Warranty covers subfloor moisture resistance but does not cover damage from flooding or other surface moisture contamination.

CAUTION: Do not sand, scour or abrade any material that is suspected of containing asbestos fibers. Asbestos is known to cause cancer. Federal law requires that asbestos be handled by a licensed and certified hazardous materials contractor.

Product SKUs


Part NumberUPCCase UPCSizeWeightUnits Per PackagePackages Per Pallet
9234 0370830923494 Gallon Pail44.12136

Caution Statement


WARNING. Causes skin and eye irritation. Wear protective gloves, and eye or face protection. Wash hands thoroughly after handling. FIRST AID: IF ON SKIN: Wash with plenty of soap and water. Take off contaminated clothing and wash before reuse. IF SKIN IRRITATION OCCURS: Get medical attention. IF IN EYES: Rinse cautiously with water for several minutes. Remove any contact lenses and continue rinsing. IF EYE IRRITATION PERSISTS: Get medical attention. For additional information, refer to Safety Data Sheet.

Warranty Statement


Franklin International will honor the applicable terms of any resilient floor manufacturer’s current published adhesive warranty or subfloor moisture warranty (where applicable) when the flooring was installed using Titebond 920 Clear Thin-Spread Tile Adhesive in accordance with product instructions and the instructions of the resilient floor manufacturer.*

Franklin International will also warrant Titebond 920 to be free from defects in materials and workmanship for a period of one year from the date of manufacture, if the product has been installed in accordance with the Franklin Specification Guide and the installation instructions furnished with the product. In the event of loss of adhesion of Titebond 920 due to product defect, Franklin International will reimburse the customer for the cost of labor and materials necessary to repair or replace the affected area(s) of the installed resilient flooring.

* Any and all addendums or changes to the vinyl floor manufacturer’s warranties will be reflected in the execution of Franklin International’s warranty immediately upon release by the vinyl floor manufacturer. The effective date of said changes and addendums will dictate coverage by Franklin International in relations to the date of installation.

As Franklin International is honoring the applicable terms of all vinyl floor manufactures’ current published warranties, Franklin International will also require the same jobsite preparations and installation instructions that accompany each warranty in question.

Important Notice: Our recommendations, if any, for the use of this product are based on tests believed to be reliable. Since the use of this product is beyond the control of the manufacturer, no guarantee or warranty, expressed or implied, is made as to such use or effects incidental to such use, handling or possession or the results to be obtained, whether in accordance with the directions or claimed so to be. The manufacturer expressly disclaims responsibility therefore. Furthermore, nothing contained herein shall be construed as a recommendation to use any product in conflict with existing laws and/or patents covering any material or use.

2020 Bruck Street, Columbus, Ohio 43207
CUSTOMER SERVICE 1-800-669-4583
TECH SERVICE 1-800-347-4583
www.titebond.com

Franklin International